Inquiry #1: Project Layout sheet call out for Buried end anchors for the MGS. But nothing is shown in the quantity sheet for this to be a non-pay item. Will Caltrans be issue addendum to reflect the payment for these guardrail terminals?
Inquiry submitted 09/12/2022

Response #1:(BI#1)-Your inquiry has been received and is being reviewed.

Response posted 09/13/2022


Response #2:(BI#1)-Attention is directed to section 83-2.02D Payment of the Standard Specifications, which states buried post anchors are included in the payment quantity for midwest guardrail system.
Response posted 09/13/2022




Inquiry #2: Several of the files for this project are not downloadable. Can the department put files into a more user-friendly format, or dropbox type link?
Inquiry submitted 09/14/2022

Response #1:(BI#2)-Most files are in ".pdf" format. We tested and opened .pdf files, with no problems. Other file formats are; .xml, .ppf , and .dgn (design) are all fine.
Response posted 09/14/2022




Inquiry #3: Please verify the Steel Soldier Pile (HP 14 x 89) quantity for Retaining Wall "C". We are coming up with slightly higher than the EE based on the provided Pile Data Table.

If this figure is incorrect, does this effect other related quantities.

Inquiry submitted 10/20/2022

Response #1:(BI#3)-Your inquiry has been received and is being reviewed.

Response posted 10/20/2022


Response #2:(BI#3)-This issue will be resolved in a forthcoming addendum.


Response posted 10/25/2022


Response #3:(BI#3)-Refer to Addendum #2, dated October 31, 2022.
Response posted 11/01/2022




Inquiry #4: ITEM #133, RAIL ELEMENT WALL (LF)- 900 LF:
Plan sheet C-3 (27/272) gives details for the REWs. This sheet indicates that the height (H) of the Walls could be 12", 18" or 24". I find no information in the Plans giving the H dimension for any of the seven (7) REWs. Please provide the H dimension for each Wall.

Inquiry submitted 10/26/2022

Response #1:(BI#4)-Your inquiry has been received and is being reviewed.

Response posted 10/27/2022


Response #2:(BI#4)-An addendum will be forthcoming to address this inquiry.
Response posted 10/27/2022




Inquiry #5: Given the changes made in Addm # 2, what bid item covers the conduits shown in the Concrete Barriers (on sheets 119,135,150,165 and 177)?
Inquiry submitted 10/31/2022

Response #1:(BI#5)-Your inquiry has been received.  However, please be aware due to the short time frame between when this inquiry was received and the bid opening, there may not be time to provide a response.  If no additional response is posted, please bid per the current contract documents.

Response posted 10/31/2022


Response #2:(BI#5)-Attention is directed to the Electric System table on sheet 106 of the plans and Item No. 153 - Electric System on the Bid Item List.
Response posted 11/01/2022




Inquiry #6: Item 86: Structural Concrete, Barrier Slab
Item is listed as final pay but sheet 119 Barrier Slab Details shows the thickness varies on the inside edge. What did Caltrans use to establish the bid quantity?

Inquiry submitted 10/31/2022

Response #1:(BI#6)-Your inquiry has been received.  However, please be aware due to the short time frame between when this inquiry was received and the bid opening, there may not be time to provide a response.  If no additional response is posted, please bid per the current contract documents.

Response posted 11/01/2022


Response #2:(BI#6)-Please refer to sheet 119 of 194 of the contract plans. The minimum thickness of the slab is 1’-8” and from there the thickness varies based on the cross-slope. The bottom of slab is flat. Bid per the current contact documents.
Response posted 11/03/2022




Inquiry #7: Can the wire mesh for the lagging be galvanized vs epoxy coated. As shown on sheet 116 of 172 (and other locations).
Inquiry submitted 11/01/2022

Response #1:(BI#7)-Your inquiry has been received.  However, please be aware due to the short time frame between when this inquiry was received and the bid opening, there may not be time to provide a response.  If no additional response is posted, please bid per the current contract documents.

Response posted 11/01/2022


Response #2:(BI#7)-Refer to section 4-1.07B “Value Engineering Change Proposal,” of the Standard Specifications. Proposals for modifications to the contract documents may be submitted to the Engineer after contract award.
Response posted 11/02/2022


The information provided in the responses to bidder inquiries is not a waiver of Section 2-1.07, "JOB SITE AND DOCUMENT EXAMINATION" of the Standard Specifications or any other provision of the contract, nor to excuse the contractor from full compliance with the contract. Bidders are cautioned that subsequent responses or contract addenda may change a previous response.