Inquiry #1: As per section 2 Bidding, Sheet 13 of the specials, it is stated in Supplemental Project Information, that a Digital Terrain model in 3-D DGN or LandXML as well as a Digital design model in LandXML would be made available. However on the pull down under Notice to Bidders and Special Provisions of downloadable files the only XML Files available are for project alignments with no elevation data such as centerline, edge of pavement, etc. Can the existing ground surface and digital design model with elevation data in XML format be added to the pull down under Notice to Bidders and Special Provisions.
Inquiry submitted 02/10/2020

Response #1:
(#1)-Your inquiry has been received and is being reviewed.
Response posted 02/11/2020


Response #2:
An addendum has been issued to address this bidder inquiry. Please refer to Addendum No. 1, issued on Monday, March 9, 2020. Please bid per the current contract documents.

Response posted 03/09/2020




Inquiry #2: The CA High Design Manual Section 850-34 dated December 30th, 2015 warns against specifying plastic pipe in areas with a potential for fire. This project lists Alternative Pipe Culvert in the Bid Schedule. Will Caltrans still allow for plastic pipe to be used on this project?
Inquiry submitted 02/14/2020

Response #1:
(#2)-Your inquiry has been received and is being reviewed.
Response posted 02/14/2020


Response #2:
Your attentions is directed to the alternative pipe culvert table on sheet DQ-1. Please bid per the current contract documents.
Response posted 02/18/2020




Inquiry #3: Expanding on Inquiry #1 and in consideration of Addendum #1, please provide a design surface DGN file. The files made available by Addendum #1 are still missing design elevation data outside the alignment line.


Inquiry submitted 03/13/2020

Response #1:
(#3)-Your inquiry has been received and is being reviewed.
Response posted 03/16/2020


Response #2:
No additional information is available. Please bid per the current contract documents.
Response posted 03/18/2020




Inquiry #4: The pipe runners / end section safety end treatments for the sloped headwalls don't appear to be included in the Item 122(F) Misc Iron and Steel quantities. Are the safety end treatments included in Item 63(F)- Structural Concrete, Headwall, or in which bid item are they compensated?
Inquiry submitted 03/19/2020

Response #1:
(#4)-There is NO separate pay item for pipe runners/end section safety end treatments, the safety end treatments are included in Item 63(F)- Structural Concrete, Headwall. Please bid per the current contract documents.
Response posted 03/19/2020




Inquiry #5: We are unable to find information regarding seasonal creek flows in the Information Handout. Can anticipated creek flows be made available for use in developing the Temporary Goodrich Creek Diversion System during the allowable in-stream work period of May 15th thru October 15th?
Inquiry submitted 03/25/2020

Response #1:
(#5)-Your inquiry has been received and is being reviewed.
Response posted 03/25/2020


Response #2:
There is no additional information is available. Please bid per the current contract documents.
Response posted 03/27/2020




Inquiry #6: Drainage system 54 E on plan sheet 165 calls out 48" RCP, there is not a bid item for 48" RCP. What item will it be paid under?
Inquiry submitted 03/25/2020

Response #1:
(#6)-Your inquiry has been received and is being reviewed.
Response posted 03/25/2020


Response #2:
An addendum has been issued to address this bidder inquiry. Please refer to Addendum No. 3, issued on Friday, March 27, 2020. Please bid per the current contract documents.
Response posted 03/27/2020




Inquiry #7: On sheet DP-26 at Drainage System #54 the pipe is called out 165.7 LF of 48” RCP culvert to be installed. On Sheet DQ-31 Drainage System #54 is called out as a 48” Cured-In-Place Pipeliner. Since there is no existing pipe in this location it appears that Bid Item #108 is incorrect. Should this pipe run actually be included in the Bid item #82 48” APC? Should item #108 be deleted? Please advise which is correct.
Inquiry submitted 03/26/2020

Response #1:
(#7)-Your inquiry has been received and is being reviewed.
Response posted 03/26/2020


Response #2:
An addendum has been issued to address this bidder inquiry. Please refer to Addendum No. 3, issued on Friday, March 27, 2020. Please bid per the current contract documents.
Response posted 03/27/2020




Inquiry #8: Bid Items #77(18" APC) and #82(48" APC) are not listed under the APC chart on DQ-1. What type of pipe /and gauges if Galvanized steel?
Inquiry submitted 03/26/2020

Response #1:
(#8)-Your inquiry has been received and is being reviewed.
Response posted 03/26/2020


Response #2:
An addendum has been issued to address this bidder inquiry. Please refer to Addendum No. 3, issued on Friday, March 27, 2020. Please bid per the current contract documents.
Response posted 03/27/2020




Inquiry #9: On the bid Schedule Item # 107 is calling for a 36'' CIPP Liner. On plan page D-44 it is saying the diameter of the pipe is 30''. Please clarify what diameter the pipe is for proper bidding on this item.
Inquiry submitted 03/27/2020

Response #1:
(#9)-Your inquiry has been received and is being reviewed.
Response posted 03/27/2020


Response #2:
An addendum has been issued to address this bidder inquiry. Please refer to Addendum No. 5, issued on Friday, April 10, 2020. Please bid per the current contract documents.
Response posted 04/10/2020




Inquiry #10: The CIPP lining specification section 71-3.08B(1) says that at location 87, the minimum wall thickness for the CIPP is 2 inches or the minimum thickness shown in the authorized installation plan, whichever is greater. This will require the CIPP installed in the 30" diameter pipe to be, at a minimum, over 50mm thick, which is too thick for this diameter of CIPP and will not be possible to install. We will be unable to quote the CIPP lining on this project if this minimum thickness requirement is not removed from the specifications or reduced to something more feasible like 0.76 inches.
Inquiry submitted 03/27/2020

Response #1:
(#10)-Your inquiry has been received and is being reviewed.
Response posted 03/27/2020


Response #2:
An addendum has been issued to address this bidder inquiry. Please refer to Addendum No. 5, issued on Friday, April 10, 2020. Please bid per the current contract documents.
Response posted 04/10/2020




Inquiry #11: DQ-19 , 24" APC chart shows drainage system #31 B 53.1' run and 2ea FES 31C and 31i. DP-14 drainage system #31 shows 18" 44.4' APC as the material used and 2ea 18" FES. Please Clarify
Inquiry submitted 03/27/2020

Response #1:
(#11)-Your inquiry has been received and is being reviewed.
Response posted 03/30/2020


Response #2:
An addendum has been issued to address this bidder inquiry. Please refer to Addendum No. 5, issued on Friday, April 10, 2020. Please bid per the current contract documents.
Response posted 04/10/2020




Inquiry #12: The current staging plans do not allow the project to be built in the maximum allowable 240 working days. Please advise?
Inquiry submitted 03/30/2020

Response #1:
(#12)-Your inquiry has been received and is being reviewed.
Response posted 03/30/2020


Response #2:
No additional information is available. Please bid per the current contract documents.
Response posted 04/01/2020




Inquiry #13: Season 1 has completing the drainage work from 317+00 to 554+00 which includes DS # 51 approx 553+00. However there is no consideration for this work until Season 2, as the earthwork stops at 541+00 for season 1. Please advise when the box culvert shall be constructed? If the intent is season 1 how will the traffic be handled?
Inquiry submitted 03/30/2020

Response #1:
(#13)-Your inquiry has been received and is being reviewed.
Response posted 04/01/2020


Response #2:
An addendum has been issued to address this bidder inquiry. Please refer to Addendum No. 5, issued on Friday, April 10, 2020. Please bid per the current contract documents.
Response posted 04/10/2020




Inquiry #14: Bid Item 159 Thermoplastic Pavement Markings (Recessed)-plan sheets 444-446 show that all arrows symbols, stop legend and limit lines to be recessed. Caltrans only has detail to recess the limit lines. Is it Caltrans intentions to only recess the 134 SF of limt line only and surface apply the remaining legends and symbols? if Caltrans would like the other legends and symbols recessed can Caltrans please provide a detail with allowable peramiters to recess all remaining legends & symbols for this project? On past projects that require recessing Caltrans has only recessed the Limit Lines & Crosswalk Bars only and surface applied the legends and symbols. please advise has there is substantial cost to recess the legends and symbols. Thank you for you time on this matter.
Inquiry submitted 03/30/2020

Response #1:
(#14)-Your inquiry has been received and is being reviewed.
Response posted 04/01/2020


Response #2:
An addendum has been issued to address this bidder inquiry. Please refer to Addendum No. 5, issued on Friday, April 10, 2020. Please bid per the current contract documents.
Response posted 04/10/2020




Inquiry #15: Please provide list of pre-approved driving Shoes for the HP 14x117.
Inquiry submitted 04/01/2020

Response #1:
(#15)-Your inquiry has been received and is being reviewed.
Response posted 04/01/2020


Response #2:
The Approved Materials List does not include driving shoes. Reference section 49-2.01A(3)(b) Driving System Submittal, item 2.2 of the Standard Specifications.
Response posted 04/02/2020




Inquiry #16: 1) Revised Standard Plans D82 (CIP- RCBC) & D83B (Precast-RCBC) are provided in the project plans. Both state under the "Special Reinforcement Coverage" note that standard plans are not be used for culverts in.......... freeze thaw locations. We can't find project specific plans provided regarding the RCBC. What structural plan is to be used for the RCBC?

2) The quantities for Item 62(F)- Structural Concrete, Box Culvert and Item 71(F) Bar Reinforcing Steel (Box Culver) are consistent with the per lineal foot quantities for cast-in-place RCBC. Will precast RCBC be acceptable for Drainage System 51?

Inquiry submitted 04/01/2020

Response #1:
(#16)-Your inquiry has been received and is being reviewed.
Response posted 04/01/2020


Response #2:
An addendum has been issued to address this bidder inquiry. Please refer to Addendum No. 5, issued on Friday, April 10, 2020. Please bid per the current contract documents.
Response posted 04/10/2020


The information provided in the responses to bidder inquiries is not a waiver of Section 2-1.07, "JOB SITE AND DOCUMENT EXAMINATION" of the Standard Specifications or any other provision of the contract, nor to excuse the contractor from full compliance with the contract. Bidders are cautioned that subsequent responses or contract addenda may change a previous response.