Bidder Inquiries

Caltrans Bidding Connect Account:

Sign In (Sign in is required to access Project Plans)

Create Account (Click here to create a Caltrans Bidding Connect Account)


Viewing inquiries for 06-1E5604

Submit new inquiry for this project


Inquiry #1: Section 39-2.03B(3)(a) calls out for PG 70-10 binder for RHMA-G. Is this correct? PG 64-16 is the typical binder used for RHMA-G.
Inquiry submitted 12/06/2022

Response #1:Your inquiry has been submitted for review
Response posted 12/07/2022


Response #2:The binder specified is correct. Please place your bid in accordance with the current contract bid documents.
Response posted 12/13/2022




Inquiry #2: The details on sheet C-1 show a saw cut around the existing manholes and survey monuments. The manholes and survey monuments should be lowered prior to cold plane activities and then raised to finished grade after the RHMA. If the manholes and survey monuments are left at grade during the cold plane activity they will be 0.20' above the temporary driving surface. They will also not allow the contractor to pave the 0.10' HMA without picking up the screed at every existing frame and cover significantly affecting the HMA smoothness. Please revise the details to pre lower and raise existing manholes and survey monuments and add quantities for the numerous water valves within the project.
Inquiry submitted 12/12/2022

Response #1:Your inquiry has been submitted for review
Response posted 12/13/2022


Response #2:Please place your bid in accordance with the current contract bid documents.
Response posted 12/14/2022


The information provided in the responses to bidder inquiries is not a waiver of Section 2-1.07, "JOB SITE AND DOCUMENT EXAMINATION" of the Standard Specifications or any other provision of the contract, nor to excuse the contractor from full compliance with the contract. Bidders are cautioned that subsequent responses or contract addenda may change a previous response.