Inquiry #1: Will Caltrans allow the use of the Zoneguard Steel Barrier to be used in leu of Temporary Railing Type K?
Inquiry submitted 09/18/2019

Response #1:Submitted for consideration.
Response posted 09/18/2019


Response #2:Please bid per the current contract documents. Details and specifications for Zone guard barrier are not provided. Modifications to the contract proposed by the contractor may only be considered by the Engineer after contract award. Please refer to Section 4-1.07, Value Engineering of the Standard Specifications.
Response posted 09/24/2019




Inquiry #2: The existing contours are not shown on the Grading Plans (G-1 thru G-5). Please provide drawings with existing contours so an earthwork takeoff can be performed. Additionally, please provide electronic .xml/.dgn files to assist with takeoffs.
Inquiry submitted 09/23/2019

Response #1:Submitted for consideration.
Response posted 09/23/2019


Response #2:Please refer to Addendum No. 1, dated October 9, 2019.
Response posted 10/09/2019




Inquiry #3: 1. Caltrans’ past and current policy for HMA production in Imperial County’s desert area climatic zone is JMF design for air voids, both acceptance and design, at 5 percent +/- 1.5. Please advise if an addendum will be issued concerning air voids for HMA mixes changing the current specified air voids of 4 percent to 5 percent. This would be applicable for both the HMA Type A and RHMA-G mixes.

2. Additionally, special provisions Section 39-2.03B(a), page 80, specifies asphalt binder for RHMA-G must be PG 64-16. The Imperial County climatic zone in the desert area for PG grade designation is grade PG 70-10. Over at least the past 5 years, all RHMA-G mixes specified for the desert area of Imperial County utilized PG 70-10 as the base stock binder. Please clarify if this change will be made by issuance of an addendum.


Inquiry submitted 10/23/2019

Response #1:Submitted for consideration.
Response posted 10/23/2019


Response #2:Please refer to Addendum No. 2, dated November 1st, 2019.
Response posted 11/01/2019




Inquiry #4: As discussed in the Pre-Bid Meeting, please provide the sign in sheet from the mandatory pre-bid meeting held on 10/23.
Inquiry submitted 10/24/2019

Response #1:Submitted for consideration.
Response posted 10/24/2019


Response #2:Sign in Sheet
Response posted 10/30/2019




Inquiry #5: Refer to Plan Sheets 204 and 206. Please confirm the controller assemblies shown shall be department furnished to the contractor.
Inquiry submitted 10/25/2019

Response #1:Submitted for consideration.
Response posted 10/28/2019


Response #2:Controller assemblies for the traffic signals are department-furnished.
Response posted 11/01/2019


Response #3:Please refer to Section 6-1.02 of the Special Provisions for lists of all items that are department furnished.
Response posted 11/04/2019




Inquiry #6: Please confirm that mulch for existing Oleander plants is belong to item 52 (Basin) in the bid form.

Inquiry submitted 10/31/2019

Response #1:Submitted for consideration.
Response posted 10/31/2019


Response #2:Item #52 is GRAVEL MULCH. For work related to existing oleanders bid per contract documents (Plant Quantities and Plant Legend)


Response posted 11/01/2019




Inquiry #7: Reference to sheet ISS-1, the IRRIGATION SPRINKLER SCHEDULE shows both swing joint type III and riser type V for riser sprinkler assembly. Do they work together? Please advise.
Inquiry submitted 10/31/2019

Response #1:Submitted for consideration.
Response posted 10/31/2019


Response #2:Please bid per the current contract documents.
Response posted 11/01/2019




Inquiry #8: Regarding Inquiry #3-1-Please advise, will an addendum be issued concerning air voids for HMA Type A changing the current specified air voids of 4% to 5%?
Inquiry submitted 11/01/2019

Response #1:Submitted for consideration.
Response posted 11/04/2019


Response #2:Please bid per the current contract documents.

Response posted 11/05/2019




Inquiry #9: Drainage systems Ds24d and Ds-24c have OCP inlets,. there is no bid item for 36" Precast RCP inlet, now is this going to get paid under?
Inquiry submitted 11/04/2019

Response #1:Submitted for consideration.
Response posted 11/04/2019


Response #2:Drainage systems DS-24d and DS-25c OCP inlets are paid under Item 106 (F) Structural Concrete, Drainage Inlet and Item 139 (F) Miscellaneous Iron and Steel per Drainage Quantities Plan Sheets DQ-4 and DQ-5.
Response posted 11/05/2019




Inquiry #10: There are existing power lines and an existing 18" water line on the south side of the project site that are shown to be relocated by others per Plan Sheet U-2. There is no mention of when the utilities will be relocated, or how long the utility relocates will take to complete in the Special Provisions or Plans. The utilities are located in the area of Abutment 1, which is the first area of work for construction of the project. Will the utilities be relocated prior to contract award?
Inquiry submitted 11/05/2019

Response #1:Submitted for consideration.
Response posted 11/05/2019


Response #2:Yes. The utilities will be relocated prior to contract award.
Response posted 11/05/2019




Inquiry #11: Bid item # 42 " Basin" has no detail, specifications regarding size, depth, or locations. Please Clarify what the basin consist of
Inquiry submitted 11/06/2019

Response #1:Submitted for consideration.
Response posted 11/06/2019


Response #2:Please refer to the information on plan sheet PL-1 which shows Basin Type II for the existing oleanders with a six feet diameter.
Response posted 11/06/2019


The information provided in the responses to bidder inquiries is not a waiver of Section 2-1.07, "JOB SITE AND DOCUMENT EXAMINATION" of the Standard Specifications or any other provision of the contract, nor to excuse the contractor from full compliance with the contract. Bidders are cautioned that subsequent responses or contract addenda may change a previous response.