Viewing inquiries for 03-2H4604

Submit new inquiry for this project


Inquiry #1: Will Caltrans Provide Cross Sections for this Project?
Inquiry submitted 03/17/2020

Response #1:
(#1)-Your inquiry has been received and is being reviewed.
Response posted 03/17/2020


Response #2:
Cross Sections will not be provided. Please bid per contract documents.
Response posted 03/18/2020




Inquiry #2: On Sheet X-1 the existing section is said to be .20' - 1.00' of AC and 0.00' - 1.00' of AB. Is it possible for Cal Trans to narrow these down a little bit? The means of construction for Bid Item 16 Roadway Excavation drastically changes (Cold Mill Operations vs Earthwork Operations) based on Existing AC structural sections. If additional information is not provided it is nearly impossible to have uniformly representative bids.
Inquiry submitted 03/17/2020

Response #1:
(#2)-Your inquiry has been received and is being reviewed.
Response posted 03/17/2020


Response #2:
Existing structural section depths are based on the best available information. Please bid per contract documents.
Response posted 03/18/2020




Inquiry #3: Section 7-1.02K(6)(j)(iii) Unregulated Earth Material Containing Lead states that the RWQCB has jurisdiction over reuse of this material at locations outside the jobsite limits. Without a location given as to where the contractor should anticipate taking this material it is impossible to accurately price this work.
Inquiry submitted 03/17/2020

Response #1:
(#3)-Your inquiry has been received and is being reviewed.
Response posted 03/17/2020


Response #2:
The contract does not involve disturbing earth materials. Information is notification of existing earth materials.
Response posted 03/23/2020




Inquiry #4: THD-1 shows the use of a typical lane closure with reversible control and speed reduction and sheet E-1 shows the use of portable signal systems. Can Caltrans please clarify what the intent of sheet E-1 is?
Inquiry submitted 03/17/2020

Response #1:
(#4)-Your inquiry has been received and is being reviewed.
Response posted 03/17/2020


Response #2:
It is anticipated that a portable signal system will be needed. Sheet E-1 provides a layout for that system.

It is also anticipated that a lane closure with flagging will be needed at times by the contractor. Sheet THD-1 provides the parameters for that type of closure.
Response posted 03/19/2020




Inquiry #5: The HMA Detail Provided on X-1 shows 1.00' of HMA placed in 3 lifts. Caltrans Standard Specifications only allow a max lift thickness of 0.25'. Is it Caltrans intent to place the HMA in three lifts? If so, please issue a special provision to accommodate this detail.
Inquiry submitted 03/17/2020

Response #1:
(#5)-Your inquiry has been received and is being reviewed.
Response posted 03/17/2020


Response #2:
The bidder is referred to as Standard Specifications section 39-2.02C Construction.
Response posted 03/19/2020




Inquiry #6: Does Standard Specification Section 19-5.03B "Relative Compaction (95 Percent) Compact earthwork to a relative compaction of at least 95 percent for at least a depth of 2.5 feet below the finished grade for the width of the traveled way plus 3 feet on each side" apply to this project?
Inquiry submitted 03/27/2020

Response #1:
(#6)-Your inquiry has been received and is being reviewed.
Response posted 03/30/2020


Response #2:
Please bid per the current contract documents.
Response posted 04/01/2020




Inquiry #7: On sheet Q-1 under the roadway quantities table it shows a quantity for "Treatment BMP" HMA-O. Please clarify exactly what this is for?
Inquiry submitted 03/31/2020

Response #1:
(#7)-For this project, the HMA-O itself is considered to be the Treatment BMP. The column that the bidder is asking about indicates the area covered by the treatment BMP (the HMA-O) and is not a separate bid item.
Response posted 04/01/2020




Inquiry #8: Due to COVID-19 guidelines, stay at home orders, etc,.. Will the Contractor be allowed to submit the required GFE documents electronically? If this will be allowed, will a digital signature also be acceptable?
Inquiry submitted 04/02/2020

Response #1:
(#8)-No, there are no changes to our business practice or contract requirements at this time.
Response posted 04/02/2020




Inquiry #9: Is K-Rail for Public and Worker protection required ? If so, why is K-Rail not a Bid Item?
Inquiry submitted 04/03/2020

Response #1:
(#9)-Your inquiry has been received and is being reviewed.
Response posted 04/06/2020


Response #2:
K-rail is not specified for this project.
Response posted 04/09/2020




Inquiry #10: Would the State please consider using PCC or a composite pavement section alternative be provided for bidding purposes. We feel the life of the product would be better for the State and also save money.
Inquiry submitted 04/06/2020

Response #1:
(#10)-Please bid per the current contract documents.
Response posted 04/06/2020




Inquiry #11: Sheet X-1 shows that existing structural section is Var. 0.20'-1.00' AC and Var. 0.00' - 1.00' AB. Is it correct to interpret this that there is a minimum 1.00' existing structural section of combined AB and AC or only that there is a guaranteed minimum 0.20' existing section?
Inquiry submitted 04/07/2020

Response #1:
(#11)-Your inquiry has been received and is being reviewed.
Response posted 04/07/2020


Response #2:
The existing structural section is based on the best information available as shown on nearby as-built plans. Based on as-built plans the minimum AC thickness is 0.2'. It is not guaranteed that the minimum structural section is 1 foot.
Response posted 04/09/2020




Inquiry #12: For Bid Item #13 - Temporary Fiber Roll, is the fiber roll allowed to remain in place permanently or is it required to be removed / disposed of?
Inquiry submitted 04/07/2020

Response #1:
(#12)-Your inquiry has been received and is being reviewed.
Response posted 04/07/2020


Response #2:
Temporary Fiber Rolls may not remain permanently.
Response posted 04/08/2020




Inquiry #13: Reference is made to section 12-3.35 of the special provisions. Will the Department please specify how many detection devices and PCMS will be needed to satisfy the specifications for the AWIS? While it's clear what the system needs to do, there is no information on quantities of the euquipment.
Inquiry submitted 04/08/2020

Response #1:(#13)-Contractor's attention is directed to Section 12-3.32C and 12-3.37 of the Special Provision, Revised Standard Specifications, and Standard Specification.
Response posted 04/08/2020


The information provided in the responses to bidder inquiries is not a waiver of Section 2-1.07, "JOB SITE AND DOCUMENT EXAMINATION" of the Standard Specifications or any other provision of the contract, nor to excuse the contractor from full compliance with the contract. Bidders are cautioned that subsequent responses or contract addenda may change a previous response.